INTRODUCTION
Panel Specications
1.1 Power Supply
Transformer Input: Wire-in — 16.5 VAC 40 VA, Model 320
Plug-in — 16.5 VAC 40 VA, Model 321
Standby Battery: 12 VDC 7.0 Ah (40 VA transformer charges up to 2 batteries)
Auxiliary Output: 12 VDC at 500mA
Bell Output: 12 VDC at 1.5 Amps
Smoke Detector Output: 12 VDC at 100mA
All circuits inherent power limited
1.2 Communication
Built-in SDLC Digital Dialer communication to DMP Model SCS-1 and SCS-1R Receivers
Built-in 4-2 communication to non-DMP receivers
Built-in M2E (Radionics Modem IIe) communication to non-DMP receivers
Built-in CID (Contact ID) communication to non-DMP receivers
Any panel can operate as a local system.
1.3 Panel Zones
Nine 1k Ohm EOL burglary zones: zones 1 to 9 on XR20 and XR40 panels, and zones 1 to 5 on the XRSuper6.
One 3.3k Ohm EOL Class B powered re zone with reset capability: zone 6 on the XRSuper6, and zone 10 on
XR20 and XR40 panels.
1.4 Keypads
You can connect up to four supervised keypads to the XRSuper6/XR20 panels and eight supervised keypads on
the XR40.
• 16 or 32-character alphanumeric keypads
• 10-zone LED keypads
In addition, the following zone expanders can be added to the XRSuper6/XR20/XR40 panels:
• One, four, eight and 16-zone expansion modules
• Single-zone PIR and glassbreak detectors
• One 738A Ademco Wireless interface for up to 32 points of zone expansion
• One FA426 Wireless receiver for up to 16 points of zone expansion (Two FA426 on the XR40)
When using the FA426 Wireless Receiver, you can add unsupervised devices to address ve of the XRSuper6
and XR20.
1.5 Outputs
The XRSuper6/XR20/XR40 panels provide four open collector outputs rated for 50mA each. A Model 300
Output Harness is required. The open collector outputs provide the ground connection for a positive voltage
source.
1.6 Enclosure Specications
The XRSuper6/XR20/XR40 panel ships in an enclosure with EOL resistors, battery leads, user’s guide, and
programming sheet. All enclosures are constructed using 20-gauge cold rolled steel except where noted.
Model 340 Enclosure
Enclosure size: 12.5” W x 9.5” H x 2.75” D
Color: Gray (G)
Model 349 Enclosure
Enclosure size: 12.5” W x 11.25” H x 3.5” D
Color: Gray (G) or Red (R)
Model 341 Enclosure
Enclosure size: 12.75” W x 6.55” H x 2.9” D
Color: Gray (G)
Model 342 Enclosure
Enclosure size: 11” W x 5” H x 2.75” D
Color: Gray (G)
Model 350A Enclosure
Enclosure size: 17.1” W x 13.2” H x 3.7” D
Color: Gray (G)
Construction: 18-gauge with 16-gauge door